ArticlesMotorBoating May 2009Vincent Daniello suggests that you can "Lightning-Proof Your Boat", but not using just bonding and a ground plate as has generally been accepted. After discussing the damage to a friend's properly bonded and grounded 60' fisherman, he concludes that the problem was with the "exit ramp". Lightning exit points through the engine, bow thruster and shore power connection resulted in disturbing outcomes such as "The bow thruster was activated and was stuck running hard to port. " He then takes the reader on a comprehensive guided tour through the components and installation of a system based on external conductors and grounding. You can download a pdf file for the full article here.Boat US Exchange October 2007"Protect a Boat Like a Building" is Ewen Thomson's mantra in this discussion of the new methods described in the latest edition of the lightning protection standard for watercraft published by the National Fire Protection Association - Chapter 8 in NFPA780-2008. In a building the convention for many decades has been to place the lightning conductors - rods on the roof, down conductors, and ground rods - on the outside. Older marine standards have tended to favor a single rod, down conductor, and ground plate right through the middle of the boat. Not surprisingly to ground-based lightning system engineers this technique tends to promote sideflashes through the hull and extensive electronics damage. Thomson's article walks us through the observations, concepts and implementation in a marine system.Panbo October 2006This on-line article by Ben Ellison is one of the earliest to describe our first system on the passagemaker John Henry. This was a follow-on from his 2003 article which was a general description of the subject.Sea Grant pamphlet & video July 1992"Lightning & Sailboats" (SGEB-17) is the layman's version of Ewen's 1991 IEEE article. The 23-minute "Lightning and Sailboats" video accompanying this pamphlet is available for $15 from IFAS.IEEE Trans EMC May 1991After analyzing both existing standards and the underlying science, Dr. Ewen Thomson wrote "A Critical Assessment of the U.S. Code for Lightning Protection of Boats" when he was an Associate Professor and lightning researcher in the Department of Electrical Engineering at the University of Florida. This peer-reviewed paper uses actual damage data provided by the owners of sailboats struck by lightning to further the science and gain insights into factors such as water salinity and conductor size. This was ten years before he invented the Siedarc TM electrode so that the theory applied does not reflect our present understanding of the importance of charge accumulation both on the boat and on the water surface. Specifically voltages were assumed to form as a result only of current flow in the water whereas in many cases the damage caused by sideflashes is consistent with sparks that precede, and sometimes supercede, any current flow from immersed ground plates and keels. |
Marine Lightning Protection Inc.3215 NW 17th StreetGainesville Florida 32605 |
|
Phone: +1 352 373-3485
Email: info@marinelightning.com URL: www.marinelightning.com |